1.
Chinese Journal of Medical Instrumentation ; (6): 323-325, 2022.
Article in Chinese | WPRIM | ID: wpr-928913

ABSTRACT

OBJECTIVE@#10 instructions of infusion pumps were contrasted and analyzed in order to explore the problems of instructions, furthermore improve the product safety.@*METHODS@#Analyzed the scopes of application, requirements of infusion apparatus, maintenance methods and cycles, battery maintenance, and service life, etc.@*RESULTS@#There were 5 products in 10 which did not indicate contraindications. One product only provided the thickness range of the tube wall of the infusion apparatus instead of specific brands. The cleaning cycles of 9 products varied from 2 to 12 months. One product did not clarify the service life.@*CONCLUSIONS@#It is recommended that manufactures should improve the product instructions to ensure the safety of infusion pumps.


Subject(s)
Electric Power Supplies , Infusion Pumps , Risk Assessment
2.
Chinese Journal of Medical Instrumentation ; (6): 233-236, 2022.
Article in Chinese | WPRIM | ID: wpr-928895

ABSTRACT

OBJECTIVE@#Analyze and conclude the new quality control process, so as to improve the quality control efficiency.@*METHODS@#Statistical analysis was conducted on the flow rate quality control data of infusion pump in 2020, with a total of 330 times of quality control data.@*RESULTS@#The pump with qualified flow rate entered and maintained the qualified state from the third minute, while the pump with unqualified flow rate entered and maintained the unqualified state from the second minute.@*CONCLUSIONS@#Take the third minute to enter the qualified range and continue for 2 minutes to judge that the flow rate quality control is qualified. The accuracy of this new rule is as high as 100%, and the time of flow rate quality control can be reduced from 60 minutes to 10 minutes, which greatly improves the work efficiency.


Subject(s)
Infusion Pumps , Quality Control
3.
Rev. Esc. Enferm. USP ; 55: e03712, 2021. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1250729

ABSTRACT

ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher's exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice.


RESUMEN Objetivo: Analizar la usabilidad de dos modelos de bombas de infusión en una Unidad de Cuidados Intensivos Pediátricos. Método: Estudio transversal con abordaje descriptivo exploratorio cuantitativo. Se realizó una tarea en ambiente controlado utilizando la bomba de infusión con 72 integrantes del equipo de enfermería de agosto a septiembre de 2018. Como base, se siguió la guía metodológica para los estudios de evaluación de Equipos de Asistencia Médica y el modelo de calidad en uso propuesto por NBR ISO/IEC 9126-1 Se utilizó análisis estadístico descriptivo, aplicando Test Exacto de Fisher, Test Binomial y Test de Mann-Whitney. Resultados: Hubo 91,7% de tareas completadas. El modelo de bomba de infusión-2 se asoció (p <0,001) con la operatividad, las tareas cumplidas con no conformidades, el uso de la calculadora manual (medida de efectividad) y el tiempo para completar la tarea (medida de eficiencia). Conclusión: Las medidas de eficacia y eficiencia pueden mostrar un mejor contexto de usabilidad de las bombas de infusión e identificar fallas de interacción con el equipo de enfermería para mejorar en la práctica asistencial.


RESUMO Objetivo: Analisar a usabilidade de dois modelos de bomba de infusão em Unidade de Terapia Intensiva Pediátrica. Método: Estudo com delineamento transversal de abordagem quantitativa do tipo descritivo exploratório. Realizou-se em um ambiente controlado uma tarefa utilizando a bomba de infusão com 72 integrantes da equipe de enfermagem no período de agosto a setembro de 2018. Como base, seguiu-se a diretriz metodológica para estudos de avaliação de Equipamentos Médicos-Assistenciais e o modelo de qualidade em uso proposto pela NBR ISO/IEC 9126-1. Utilizou-se a análise estatística descritiva, aplicando o Teste Exato de Fisher, o Teste Binomial e o Teste de Mann-Whitney. Resultados: Constataram-se 91,7% de tarefas cumpridas. O modelo da bomba de infusão-2 apresentou associação (p < 0,001) com a operacionalização, tarefas cumpridas com não conformidades, uso da calculadora manual (medida eficácia) e o tempo para cumprir a tarefa (medida eficiência). Conclusão: Medidas de eficácia e eficiência podem evidenciar um melhor contexto de usabilidade de bombas de infusão e identificar falhas de interação com a equipe de enfermagem a serem aprimoradas na prática assistencial.


Subject(s)
Pediatric Nursing , Intensive Care Units, Pediatric , Quality of Health Care , Technology Assessment, Biomedical , Infusion Pumps , Ergonomics
4.
Rev. colomb. ortop. traumatol ; 35(3): 244-252, 2021. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1378685

ABSTRACT

Introducción El reemplazo de hombro es efectivo para mejorar el dolor y la funcionalidad en patologías crónicas del hombro. Considerando los riesgos y costos asociados a la estancia hospitalaria, realizar este procedimiento de forma ambulatoria surge como una opción para optimizar esta estrategia terapéutica. Materiales & Métodos Estudio observacional descriptivo prospective de pacientes operados por un mismo cirujano con artroplastia de hombro ambulatoria (RHA) utilizando analgesia regional con bomba de infusión elastomérica. Se registraron las escalas de ASES y SANE, el dolor, la satisfacción del paciente, las complicaciones y reingresos a 90 días. Resultados Se intervinieron 10 pacientes de un promedio de edad de 59.6 (±3.9) años, siendo el 40% prótesis anatómicas, 50% reversas y 10% hemiartroplastia. Al cuarto día postoperatorio el dolor por EVA fue 1,3 (±0,62) y al décimo día 2,7 (±1,1). La puntuación SANE antes del procedimiento fue de 31 (±9,7), y 90 días después fue de 76,1 (±6,8). Todos los pacientes refirieron una alta satisfacción. Un paciente al 3er día presentó un episodio de broncoespasmo leve, tratado de forma ambulatoria. Un paciente presentó una infección superficial que mejoró completamente con el antibiótico oral. No se presentaron reingresos o consultas a urgencias a 90 días. Discusión Se presentan los desenlaces a corto plazo de la primera serie de casos en nuestro medio de RH ambulatorio. Este procedimiento puede ser realizado de forma segura, siguiendo un protocolo estandarizado y realizando una juiciosa selección de los pacientes.


Background Shoulder arthoplasty is an effective procedure to improve pain and function in chronic shoulder pathologies. Considering the risks and costs associated with hospital stay, performing joint replacements on an outpatient setting emerges as an option to optimize this therapeutic strategy. Methods A prospective analysis was performed in 10 patients undergoing same-day discharge total shoulder arthroplasty with anatomic and reverse prostheses. Pain was managed with a continuous peripheral interscalene block using an elastomeric infusion pump. ASES and SANE scores, pain, patient satisfaction, complications, and readmissions after 90 days were recorded. Results 10 patients (average age 59.6 (±3.9) years) underwent outpatient shoulder arthroplasty (50% reverse shoulder arthroplasty, 40% total shoulder arthroplasty and 10% hemiarthroplasty). On post-operative day 4, mean visual analogue scale (VAS) for pain assessment was 1.3 (±0.62) and day 10, 2.7 (±1.1). Pre-operative SANE score was 31 (±9.7), and 90 days after the procedure was 76.1 (±6.8). All patients were satisfied with the procedure. One patient had a mild bronchospasm on day 3 that resolved with bronchodilators on an outpatient basis. One patient had a superficial surgical site infection that resolved completely with oral antibiotics administration. There were no re-admissions or major complications.


Subject(s)
Humans , Arthroplasty, Replacement, Shoulder , Infusion Pumps , Ambulatory Surgical Procedures
5.
Rev. Pesqui. (Univ. Fed. Estado Rio J., Online) ; 13: 1428-1435, jan.-dez. 2021. ilus
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1342109

ABSTRACT

Objetivo: identificar as causas da fadiga de alarmes em estudos de usabilidade de bomba de infusão em terapia intensiva pediátrica. Métodos: Realizou-se uma revisão integrativa nas bases de dados LILACS, SciELO, IBECS, SCOPUS e MEDLINE. Resultados: Foram identificadas 1.164 publicações e selecionados seis estudos primários que emergiram em duas temáticas: compreender as causas dos alarmes da bomba de infusão que constou: biblioteca de fármacos incompleta, limites absolutos e relativos rígidos, falta de protocolo de preparo e administração de medicação, período de férias dos funcionários; e as medidas que podem evitar a fadiga de seus alarmes.Conclusão:falhas na usabilidade de bombas de infusão aumentam os alarmes desnecessários que podem promovem sua fadiga. A utilização segura de bombas de infusão demanda uma equipe que monitore suas práticas e atue promovendo mudanças no contexto de trabalho


Objective: to identify the causes of alarm fatigue in studies of infusion pump usability in pediatric intensive care. Methods: an integrative review was carried out in the LILACS, SciELO, IBECS, SCOPUS and MEDLINE databases. Results: 1,164 publications were identified and six primary studies were selected that emerged in two themes: understanding the causes of the infusion pump alarms that consisted of: incomplete drug library, absolute and strict relative limits, lack of preparation protocol and medication administration, employee vacation period; and measures that can prevent fatigue from your alarms. Conclusion: the causes of alarm fatigue involve low user interaction with the equipment, inadequate work processes and low investment in preventive measures for its occurrence The safe use of infusion pumps requires a team to monitor their practices and act by promoting changes in the work context


Objetivo: identificar las causas de la fatiga de alarma en estudios de usabilidad de bombas de infusión en cuidados intensivos pediátricos. Métodos: se realizó una revisión integradora en las bases de datos LILACS, SciELO, IBECS, SCOPUS y MEDLINE. Resultados: se identificaron 1.164 publicaciones y se seleccionaron seis estudios primarios que surgieron en dos temas: comprender las causas de las alarmas de la bomba de infusión que consistían en: biblioteca de medicamentos incompleta, límites relativos absolutos y estrictos, falta de protocolo de preparación y administración de medicamentos, período de vacaciones de los empleados; y medidas que pueden prevenir la fatiga de sus alarmas. Conclusión: las causas de la fatiga de las alarmas involucran baja interacción del usuario con el equipo, procesos de trabajo inadecuados y baja inversión en medidas preventivas para su ocurrencia. El uso seguro de las bombas de infusión requiere que un equipo monitoree sus prácticas y actúe promoviendo cambios en el contexto de trabajo


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Infusion Pumps/standards , Intensive Care Units, Pediatric , Alert Fatigue, Health Personnel/prevention & control , Occupational Stress/prevention & control
6.
J. vasc. bras ; 20: e20200191, 2021. tab, graf
Article in English | LILACS | ID: biblio-1279371

ABSTRACT

Abstract Background The contrast power injector (CPI) is the gold standard method for injecting contrast with the pressure and flow needed to generate a satisfactory images during endovascular procedures, but it is an expensive tool, narrowing its wide-scale applications. One alternative is the manual injection (MI) method, but this does not generate the pressure required for adequate visualization of anatomy. It is therefore imperative to create an alternative low-cost method that is capable of producing high quality images. Objectives To compare the injection parameters of a new mechanical device (Hand-Crank) created in a university hospital with the MI method and with the contrast power injector's ideal values. Methods A circulation phantom was constructed to simulate the pressure in the aorto-iliac territory and the injection parameters of the two methods were compared in a laboratory setting. Student's t test and the Mann-Whitney test were used for statistical analysis. Three vascular surgery residents (the authors) performed the injections (each performed 9 tests using conventional manual injection and 9 tests using the Hand-Crank, totaling 54 injections). Results There were statistical differences between the two methods (p<0.05) in total volume injected until maximum pressure was attained, pressure variation, maximum pressure, total injection time, and time to reach the maximum pressure. Conclusions The Hand-Crank can achieve higher maximum pressure, higher average flow, and lower injection time than the manual method. It is a simple, low-cost, and effective tool for enhancing injection parameters in an experimental setup. It could help to produce higher quality images in a clinical scenario.


Resumo Contexto A bomba injetora é o método padrão-ouro para a injeção de contraste em aortografias. Entretanto, é uma ferramenta de alto custo, o que limita o seu uso. A injeção manual surge como alternativa, mas a pressão gerada com esse método é baixa, e, por isso, a qualidade das imagens não é usualmente satisfatória. Assim, a criação de um método de baixo custo capaz de gerar imagens de qualidade é imperativo. Objetivos Comparar os parâmetros de injeção de um novo dispositivo mecânico (manivela articulada) criado em um hospital universitário com os parâmetros da injeção manual e com os valores ideais da bomba injetora. Métodos Um simulador do território aórtico foi construído, e parâmetros de injeção entre os diferentes métodos em um cenário laboratorial controlado foram analisados. O teste t de Student e o teste de Mann-Whitney foram usados para análise estatística. Três residentes de Cirurgia Vascular realizaram os testes (nove usando o novo dispositivo, e nove usando a injeção manual, totalizando 54 injeções). Resultados Houve diferença estatisticamente significativa (p < 0,05) entre os dois métodos, considerando os parâmetros: variação de pressão, pressão máxima, tempo de injeção, tempo até a pressão máxima e volume até a pressão máxima. Conclusões A manivela articulada atingiu níveis superiores de pressão e de velocidade de injeção, com menor tempo de injeção do que a injeção manual. É um dispositivo simples, de baixo custo e com resultados comparáveis à bomba injetora, o que sugere seu uso potencial na geração de imagens satisfatórias em aortografias.


Subject(s)
Infusion Pumps , Radiology, Interventional/instrumentation , Contrast Media/administration & dosage , Vascular Surgical Procedures , Angiography/instrumentation , Low Cost Technology , Costs and Cost Analysis , Endovascular Procedures , Injections/instrumentation
7.
China Journal of Orthopaedics and Traumatology ; (12): 63-67, 2021.
Article in Chinese | WPRIM | ID: wpr-879407

ABSTRACT

OBJECTIVE@#To compare the clinical outcomes of hydraulic perfusion pump and traditional water fhushing in percutaneous endoscopic lumbar discectomy.@*METHODS@#From January 2016 to December 2018, 72 patients with lumbar disc herniation failed to conservative treatment were enrolled in this study. The patients were divided into hydraulic perfusion pump group and traditional water flushing group, 36 cases in each group. There were no significant differences in gender, age, prominent segment, clinical classification, preoperative visual analogue scale (VAS) and Japanese Orthopaedic Association(JOA) score between two groups (@*RESULTS@#All the patients were followed up for 12 to 24 (15.7±5.1) months. Compared with the traditional water flushing group, the operation time of the hydraulic perfusion pump group was shorter [(65.5±21.3) min vs (74.8±19.9) min, @*CONCLUSION@#Both hydraulic perfusion pump and traditional water flushing assisted percutaneous endoscopic lumbar disc herniation can achieve satisfactory clinical results, but the former has shorter operation time, clearer intraoperative vision, less bleeding, and fewer intraoperative and postoperative complications.


Subject(s)
Humans , Diskectomy , Diskectomy, Percutaneous , Endoscopy , Infusion Pumps , Intervertebral Disc Displacement/surgery , Lumbar Vertebrae/surgery , Retrospective Studies , Treatment Outcome , Water
8.
Notas enferm. (Córdoba) ; 20(36): 70-77, nov.2020.
Article in Spanish | LILACS, BDENF, BINACIS, UNISALUD | ID: biblio-1140731

ABSTRACT

Introducción. Este espacio es acerca del empleo de bombas elastoméricas en la administración de citostáticos de infusión continua con pacientes oncológicos que reciben tratamiento endovenoso, de infusión continua en el domicilio, mejorando así la calidad de vida del paciente, (esta experiencia es sólo en relación a aplicación de 5 fluorouracilo).Material y método: Al inicio, la primera dosis de quimioterapia, se realiza en el internado común para observar la tolerancia a la medicación, y en la segunda o tercera aplicación se realiza la misma en el hospital de día la primera parte del esquema, y luego se realiza la conexión de la bomba elastomérica que infundirá durante 46hs con el 5 fluorouracilo. El paciente asistirá al hospital oncológico para realizar la desconexión. Nuestro rol enfermero de contención y capacitación es necesario y así poder asegurar el buen manejo del dispositivo y brindar seguridad a los pacientes, para que logren un cuidado autónomo, seguro y eficaz. Para tal fin se les provee un instructivo. Poseer catéter implantable es requisito obligatorio para esta modalidad. Beneficios encontrados: es portátil y ergonómico, Mejora la movilidad y autocuidado, tasa de infusión exacta. Características de seguridad, que incluyan la protección del reservorio frente a posibles daños; Descomprimimos las internaciones, reducimos la espera de camas para internación de pacientes. Reducimos el uso de bombas comunes eléctricas del internado quedando a disponibilidad para otros pacientes hospitalizados. Dificultades halladas: Desconocimiento del paciente sobre el insumo (bomba). Inseguridad del paciente al encontrarse en el hogar por primera vez. Trámites burocráticos para autorización de la bomba. Conclusión: esta implementación innovadora requiere aún más aprendizaje, contamos con el apoyo del Departamento de Enfermería y la jefatura del servicio del Hospital de Día Oncológico, para el uso de las bombas. Para esta experiencia se utilizaron 10 bombas elastoméricas. Experiencia práctica, positiva para el paciente, además él mismo se compromete con su autocuidado y tratamiento, se logra evitar las exposiciones nosocomiales minimizando así los riesgos de contagios. Reducimos el uso de bombas comunes eléctricas del internado quedando a disposición para otros pacientes que lo requieran. Descomprimimos el internado común permitiendo así contar con más camas y mayor fluidez para satisfacer la demanda de internación de pacientes con otras patologías[AU]


Introduction. This space is about the use of elastomeric pumps in the administration of cytostatics of continuous infusion with cancer patients who receive intravenous treatment, of continuous infusion of qmt at home, thus improving the quality of life of the patient, (this experience is only in relation to to application of 5 fluorouracil). Material and method: At the beginning, the first dose of chemotherapy is carried out in the common boarding school to observe the tolerance to the medication, and in the second or third application it is carried out in the day hospital the first part of the scheme, and then the elastomeric pump is connected, which will infuse for 46 hours with 5 fluorouracil. The patient will attend the cancer hospital at hour 46 to perform the disconnection. Our nursing role of containment and training is necessary in order to ensure the proper handling of the device and provide safety to patients, so that they achieve autonomous, safe and effective care. For this purpose, an instruction manual is provided. Having an implantable catheter is a mandatory requirement for this modality; Benefits found: It is portable and ergonomic, Improves mobility and self-care, exact infusion rate. Safety features, including protection of the reservoir against possible damage; We decompressed hospitalizations, we reduced the wait for beds for patient admission. We reduced the use of common electric pumps in the internship, making them available for other hospitalized patients. Difficulties encountered: Lack of knowledge of the patient about the input (pump). Patient insecurity when being at home for the first time. Bureaucratic procedures for authorization of the pump. Conclusion. This innovative implementation requires even more learning, we have the support of the Nursing Department and the head of the Oncology Day Hospital service, for the use of the pumps. For this experiment 10 elastomeric pumps were used. Practical experience, positive for the patient, he also commits himself to self-care and treatment, it is possible to avoid nosocomial exposures, thus minimizing the risks of contagion. We reduce the use of common electric pumps in the internship by being available for other patients who require it. We decompress the common boarding school, thus allowing us to have more beds and greater fluidity to satisfy the demand for hospitalization of patients with other pathologies[AU]


Introdução. Este espaço trata da utilização de bombas elastoméricas na administração de citostáticos de infusão contínua em pacientes oncológicos que recebem tratamento intravenoso, de infusão contínua de qmtem casa, melhorando assim a qualidade de vida do paciente, (esta experiência é apenas emrelação a aplicação de 5 fluorouracil). Material e método: No início, a primeira dose de quimioterapia é realizada no colégio interno comum para observar a tolerânciaao medicamento, e na segunda ou terceira aplicação é realizada em hospital dia a primeira parte do esquema, e em seguida, a bomba elastomérica é conectada, que fará a infusão de 5 fluorouracil por 46 horas. O paciente comparecerá ao hospital oncológico na hora 46 para realizar o desligamento. Nosso papel de enfermagem de contenção e treinamento é necessário a fim de garantir o correto manuseio do dispositivo e dar segurançaaos pacientes, para que alcancem um cuidado autônomo, seguro e eficaz. Para tal, é fornecido um manual de instruções. Ter Um catéter implantável é requisito obrigatório para esta modalidade; Benefícios encontrados: É portátil e ergonômico, melhora a mobilidade e o autocuidado, taxa de infusão exata. Recursos de segurança, incluindo proteção do reservatório contra possíveis danos; Descomprimimos internações, reduzimos a espera por leitos para admissão de pacientes .Reduzimos o uso de bombas elétricas comuns no internato, disponibilizando-as para outros pacientes internados. Dificuldades encontradas: Falta de conhecimento do paciente sobre o insumo (bomba). Insegurança do paciente ao estar em casa pela primeira vez. Procedimentos burocráticos para autorização da bomba. Conclusão. Esta implementação inovadora exige ainda mais aprendizagem, contamos com o apoio do Departamento de Enfermagem e do chefe do serviço de Oncologia-Dia Hospital, para utilização das bombas. Para esta experiencia foram utilizadas 10 bombas elastoméricas. Experiência prática, positiva para o paciente, ele também se compromete com o autocuidado e o tratamento, sendo possível evitar exposições nosocomiais, minimizando assim os riscos de contágio. Reduzimos o uso de bombas elétricas comuns no estágio, disponibilizando para outros pacientes que necessitem. Descomprimimos o internato comum, permitindo assim ter Mais leitos e maior fluidez para atender a demanda de internação de pacientes como utras patologias[AU]


Subject(s)
Humans , Self Care , Infusion Pumps , Cytostatic Agents/administration & dosage , Ambulatory Care , Fluorouracil/administration & dosage
9.
Rev. enferm. UFSM ; 10: 32, 2020.
Article in English, Portuguese | BDENF, LILACS | ID: biblio-1119321

ABSTRACT

Objetivo: analisar as percepções dos profissionais de enfermagem sobre o uso da Bomba de Infusão no seu cotidiano em Terapia Intensiva. Método: estudo descritivo-exploratório de abordagem qualitativa, realizado com 15 profissionais de enfermagem da Unidade de Terapia Intensiva Adulto de um hospital-escola público do Paraná. A coleta de dados ocorreu em junho/2017, por meio de entrevistas semiestruturadas gravadas, pautadas na questão norteadora: fale-me sobre o uso da bomba de infusão no seu cotidiano de trabalho. Aos dados transcritos, empregou-se a Análise de Conteúdo. Resultados: foram pontuados aspectos positivos e negativos acerca do uso da bomba de infusão, além de sugestões gerais ao seu propósito. Considerações Finais: apesar dos entrevistados perceberem a Bomba de Infusão como viabilizadora da assertividade na infusão volêmica, existem desvantagens relacionadas ao sensor de gotas e alarme. Como sugestões de melhorias, referiam necessidade de otimizar o design da Bomba de Infusão, especialmente a programação de alarmes.


Objective: to analyze the perceptions of nursing professionals about the use of the Infusion Pump in their daily lives in Intensive Care. Method: descriptive-exploratory study, with a qualitative approach, conducted with 15 nursing professionals working in the Intensive Care Unit for Adults of a public teaching hospital in Paraná. Data collection took place in June/2017, through recorded semi-structured interviews, based on the guiding question: could tell me about the use of the infusion pump in your daily work? As for the transcribed data, Content Analysis was employed. Results: positive and negative aspects were highlighted regarding the use of the infusion pump, besides general suggestions for its purpose. Final considerations: although the interviewees perceive the Infusion Pump as a viable way for the assertiveness in volemic infusion, there are disadvantages related to the drop and alarm sensor. As for suggestions for improvements, it was mentioned the need to optimize the design of the Infusion Pump, especially the alarm programming.


Objetivo: analizar las percepciones de los profesionales de enfermería sobre el uso de la Bomba de Infusión en su vivir cotidiano en Cuidados Intensivos. Método: estudio descriptivo-exploratorio con enfoque cualitativo, realizado con 15 profesionales de enfermería de la Unidad de Cuidados Intensivos para Adultos de un hospital público de enseñanza en Paraná. La recopilación de datos ocurrió en junio/2017, mediante entrevistas semiestructuradas grabadas, basadas en la pregunta orientadora: ¿podrías contarme sobre el uso de la bomba de infusión en su trabajo cotidiano? Para los datos transcritos, se empleó el Análisis de Contenido. Resultados: se señalaron aspectos positivos y negativos acerca del uso de la bomba de infusión, además de sugerencias generales para su propósito. Consideraciones finales: aunque los entrevistados perciben que la Bomba de Infusión es viable para la asertividad en la infusión volémica, existen desventajas relacionadas con el sensor de gotas y alarma. Como sugerencias de mejoras, se mencionó la necesidad de perfeccionar el design de la Bomba de Infusión, especialmente la programación de alarmas.


Subject(s)
Humans , Infusion Pumps , Biomedical Technology , Patient Safety , Intensive Care Units , Nursing, Team
10.
Rev. Esc. Enferm. USP ; 54: e03562, 2020. tab, graf
Article in English, Portuguese | BDENF, LILACS | ID: biblio-1101392

ABSTRACT

Abstract Objective: To identify the scientific evidence on the frequency of handling errors of conventional and smart pump infusions in intravenous insulin therapy in intensive care units. Method: A systematic review with meta-analysis conducted in the Virtual Health Library, MEDLINE via PubMed, Scopus and Web of Science databases. Articles were assessed regarding the level of evidence by applying the Oxford Center for Evidence-Based Medicine Evidence Scale. Results: Twelve (12) publications were selected which met the eligibility criteria. The programming error rate using the conventional infusion pump ranged from 10% to 40.1%, and the smart pump technology error rate ranged from 0.3 to 14%. The meta-analysis of two studies favored the smart pump in reducing the relative risk of programming errors by 51%. Conclusion: Based on selected articles, the smart pump reduces the risk of programming errors.


Resumen Objetivo: Identificar las evidencias acerca de la frecuencia de errores en el manejo de las bombas de infusión convencional y smart pump en la terapia insulínica intravenosa en unidades de cuidados intensivos. Método: Revisión sistemática con metaanálisis llevada a cabo en las bases de datos Biblioteca Virtual de Saúde, MEDLINE por vía PubMed, Scopus y Web of Science. Los artículos fueron evaluados en cuanto al nivel de evidencia por la aplicación de la Escala de Evidencia del Oxford Centre for Evidence-Based Medicine. Resultados: Se seleccionaron 12 publicaciones que atendieron los criterios de elegibilidad. El índice de errores de programación utilizando la bomba de infusión convencional varió del 10% al 40,1% y en la tecnología smart pump varió del 0,3% al 14%. El metaanálisis de dos estudios fue favorable a la smart pump en la reducción del riesgo relativo de errores de programación en el 51%. Conclusión: Considerando como base los artículos seleccionados, la smart pump reduce el riesgo de errores de programación.


Resumo Objetivo: Identificar as evidências científicas acerca da frequência de erros no manuseio das bombas de infusão convencional e smart pump na terapia insulínica intravenosa em unidades de cuidados intensivos. Método: Revisão sistemática com metanálise realizada nas bases de dados Biblioteca Virtual de Saúde, MEDLINE via PubMed, Scopus e Web of Science. Os artigos foram avaliados quanto ao nível de evidência pela aplicação da Escala de Evidência do Oxford Centre for Evidence-Based Medicine. Resultados: Foram selecionadas 12 publicações que atenderam aos critérios de elegibilidade. A taxa de erros de programação usando a bomba de infusão convencional variou de 10% a 40,1% e na tecnologia smart pump variou de 0,3 a 14%. A metanálise de dois estudos foi favorável a smart pump na redução do risco relativo de erros de programação em 51%. Conclusão: Considerando como base os artigos selecionados, a smart pump reduz o risco de erros de programação.


Subject(s)
Infusion Pumps , Insulin/administration & dosage , Intensive Care Units , Medication Errors , Review , Critical Care Nursing
11.
Rev. Univ. Ind. Santander, Salud ; 51(4): 289-300, Septiembre 26, 2019. tab
Article in Spanish | LILACS | ID: biblio-1092259

ABSTRACT

Resumen Introducción: Las bombas de infusión inteligentes, constituyen una herramienta útil para la administración segura de medicamentos endovenosos dado que permiten prevenir potenciales eventos adversos. Objetivo: Evaluar la adherencia y los potenciales eventos adversos prevenidos, durante la administración de medicamentos endovenosos empleando bombas de infusión inteligentes. Metodología: Estudio observacional, realizado en cuatro unidades de cuidados intensivos usando datos del software Hospira MedNetTM. Un análisis descriptivo fue llevado a cabo junto con un análisis bivariado empleando una prueba U de Mann-Whitney, una prueba de Kruskal-Wallis y un test de Bonferroni para evaluar la adherencia y los potenciales eventos adversos prevenidos por año y servicio. Resultados: La adherencia fue del 74,0%, se presentaron 78.299 alertas de seguridad y se previnieron 4,54% (n=16.288) potenciales eventos adversos. Se encontraron diferencias entre el primer y segundo año en la adherencia [Mediana: 69,15 (Q1:64,2-Q3:75,5) Vs Mediana: 84,2(Q1:72,15-Q3:89,05), p<0.001], adherencia a la seguridad [Mediana: 87,1% (Q1:83,05-Q3:91,2) Vs Mediana: 94,05 (Q1:89,95-Q3:96,2), p<0.001] y las ediciones de alertas de limite relativo [Mediana:17,0 (Q1:8,5-Q3:24,5) Vs Mediana: 12,0 (Q1:7,0-Q3:17,5), p=0.013]. La solución salina, la norepinefrina, el lactato de ringer, la piperacilina-tazobactam, la nitroglicerina y la heparina presentaron el mayor número de alertas de seguridad. Conclusión: Se encontró una buena adherencia (uso de la farmacoteca) y adherencia a la seguridad (indicador de uso de la bomba), con una reducción de los potenciales eventos adversos; así el uso de bombas inteligentes podría contribuir en la prevención de potenciales errores durante la administración de medicamentos endovenosos en la unidad de cuidados intensivos.


Abstract Introduction: Smart infusion pumps have become a useful tool for the safe administration of intravenous medications, since they allow the prevention of potential adverse events. Objetive: To assess adherence and potential adverse events prevented during intravenous medication administration using smart infusion pumps. Methods: Observational study, conducted in four intensive care units using data from Hospira MedNetTM software. A descriptive analysis was carried out together with a bivariate analysis using a Mann-Whitney U test, a KruskalWallis test and a Bonferroni test to assess adherence and potential adverse events prevented by year and service. Results: Adherence was 74.0%, 78,299 safety alerts were presented and 4.54% (n = 16,288) potential adverse events were prevented. Differences were found between the first and second year in adherence [Median: 69.15 (Q1: 64.2-Q3:75.5) versus Median: 84.2 (Q1: 72.15-Q3: 89.05), p<0.001]. Likewise safety adherence [Median: 87.1% (Q1: 83.05-Q3: 91.2) versus Median: 94.05 (Q1: 89.95-Q3: 96.2), p<0.001] and the relative limit alert editions [Median: 17.0 (Q1: 8.5-Q3: 24.5) versus Median: 12.0 (Q1: 7.0-Q3: 17.5), p=0.013]. The saline solution, norepinephrine, ringer's lactate, piperacillin-tazobactam, nitroglycerin and heparin presented the highest number of safety alerts. Conclusions: Adequate adherence (use of the drug library) and safety adherence (indicator of pump use) were found, with a reduction in potential adverse events; thus, the use of smart pumps could contribute to the prevention of potential errors during the administration of intravenous medications in the intensive care unit.


Subject(s)
Humans , Medication Errors , Infusion Pumps , Safety Management , Administration, Intravenous
12.
Rev. bras. enferm ; 72(3): 617-623, May.-Jun. 2019. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1013549

ABSTRACT

ABSTRACT Objective: To analyze cost-effectiveness and to calculate incremental cost-effectiveness ratio of the use of infusion pumps with drug library to reduce errors in intravenous drug administration in pediatric and neonatal patients in Intensive Care Units. Methods: Mathematical modeling for economic analysis of the decision tree type. The base case was composed of reference and alternative settings. The target population was neonates and pediatric patients hospitalized in Pediatric and Neonatal Intensive Care Units, comprising a cohort of 15,034 patients. The cost estimate was based on the bottom-up and top-down approaches. Results: The decision tree, after RollBack, showed that the infusion pump with drug library may be the best strategy to avoid errors in intravenous drugs administration. Conclusion: The analysis revealed that the conventional pump, although it has the lowest cost, also has lower effectiveness.


RESUMEN Objetivo: Analizar el costo-efectividad y calcular la razón de costo-efectividad incremental del uso de bombas de infusión con una biblioteca de fármacos para reducir errores en la administración de medicamentos por vía intravenosa, en pacientes pediátricos y neonatales en unidades de terapia intensiva. Método: Modelaje matemático para el análisis económico, del tipo árbol de decisión. El caso base se compone de escenarios de referencia y alternativo. La población objetivo fueron pacientes neonatos y pediátricos internados en unidades de terapia intensiva pediátrica y neonatal, componiendo una cohorte de 15.034 pacientes. La estimación de costos se basó en los enfoques bottom-up y top-down. Resultados: El árbol de decisión, después de Roll Back, mostró que la bomba de infusión con biblioteca de fármacos puede ser la mejor estrategia para evitar errores en la administración de medicamentos intravenosos. Conclusión: El análisis reveló que la bomba convencional, aunque tiene el menor costo, tiene también menor efectividad.


RESUMO Objetivo: Analisar o custo-efetividade e calcular a razão de custo-efetividade incremental do uso de bombas de infusão com biblioteca de fármacos para reduzir erros na administração de medicamento pela via intravenosa, em pacientes pediátricos e neonatais em Unidades de Terapia Intensiva. Método: Modelagem matemática para análise econômica, do tipo árvore de decisão. O caso-base foi composto pelos cenários de referência e alternativo. A população alvo foram pacientes neonatos e pediátricos internados em Unidades de Terapia Intensiva pediátrica e neonatal, compondo uma coorte de 15.034 pacientes. A estimativa de custos foi baseada nas abordagens bottom-up e top-down. Resultados: A árvore de decisão, após RollBack, mostrou que a bomba de infusão com biblioteca de fármacos pode ser a melhor estratégia para evitar erros na administração de medicamentos intravenosos. Conclusão: A análise revelou que a bomba convencional, embora tenha o menor custo, tem também menor efetividade.


Subject(s)
Humans , Infant, Newborn , Infusion Pumps/economics , Infusion Pumps/standards , Medication Errors/prevention & control , Technology Assessment, Biomedical/methods , Brazil , Intensive Care Units, Pediatric/organization & administration , Intensive Care Units, Pediatric/statistics & numerical data , Intensive Care Units, Neonatal/organization & administration , Intensive Care Units, Neonatal/statistics & numerical data , Monte Carlo Method , Cost-Benefit Analysis , Administration, Intravenous/methods , Administration, Intravenous/standards , Medication Errors/economics , Medication Errors/nursing
13.
Rev. cuba. anestesiol. reanim ; 18(1): e535, ene.-abr. 2019. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1093095

ABSTRACT

Introducción: La anestesia y analgesia peridural continua, además de proporcionar un adecuado control del dolor posoperatorio, aportan beneficios como la disminución del riesgo de trombosis y de sangrado intraoperatorio. Objetivo: Describir el comportamiento y los resultados de la aplicación de la anestesia peridural continua mediante bomba de infusión elastomérica en pacientes intervenidas de mamoplastia de aumento. Métodos: Se realizó un estudio observacional, descriptivo, prospectivo, longitudinal en el Hospital Clínico Quirúrgico Hermanos Ameijeiras, entre febrero 2014 y febrero 2016. Resultados: 72,8 fueron las pacientes entre 20 y 29 años, 57,6 por ciento era ASA I y 78,3 por ciento normopeso. El 50 por ciento fueron operadas por hipoplasia mamaria. La frecuencia cardiaca, la tensión arterial sistólica y diastólica disminuyeron a los 5 min después de aplicarse la técnica. La media del dolor fue menor de 3 en todos los momentos evaluados. Las complicaciones inmediatas fueron escasas y leves. El 85,9 por ciento calificó la técnica como buena. Conclusiones: El comportamiento y los resultados de la aplicación de la anestesia peridural continua mediante bomba de infusión elastomérica en la mamoplastia de aumento fue estable y segura. Existieron diferencias significativas en el comportamiento de las variables hemodinámicas intraoperatorias y de la intensidad de dolor, la cual fue leve en todas sus mediciones. Las complicaciones mediatas fueron escasas y no complejas. Más de las tres cuartas partes de las pacientes evaluaron de acuerdo al grado de satisfacción de buena la efectividad de la técnica anestésica para este tipo de procedimiento quirúrgico(AU)


Introduction: Continuous epidural anesthesia and analgesia, in addition to providing adequate control of postoperative pain, provide benefits such as decreased risk of thrombosis and intraoperative bleeding. Objective: To describe the behavior and results of the application of continuous epidural anesthesia by means of an elastomeric infusion pump in patients undergoing augmentation mammoplasty. Methods: An observational, descriptive, prospective, longitudinal study was conducted at Hermanos Ameijeiras Clinical Surgical Hospital, between February 2014 and February 2016. Results: 72.8 percent were patients 20-29 years old, 57.6 percent were ASA I, and 78.3 percent had normal weight. 50 percent were operated for mammary hypoplasia. Heart rate, as well as systolic and diastolic blood pressure decreased 5 minutes after the technique was applied. The average pain was less than 3 in all the moments evaluated. The immediate complications were minimal and mild. 85.9 (AU) described the technique as good. Conclusions: The behavior and results of the application of continuous epidural anesthesia using an elastomeric infusion pump in the augmentation mammoplasty was stable and safe. There were significant differences in the behavior of intraoperative hemodynamic variables and pain intensity, which was slight in all its measurements. The mediate complications were scarce and not complex. More than three quarters of the patients evaluated, based on the degree of satisfaction, the effectiveness of the anesthetic technique as good for this type of surgical procedure(AU)


Subject(s)
Humans , Female , Adult , Infusion Pumps/standards , Mammaplasty/methods , Anesthesia and Analgesia , Anesthesia, Epidural/standards , Epidemiology, Descriptive , Prospective Studies , Longitudinal Studies
15.
The Korean Journal of Pain ; : 196-205, 2019.
Article in English | WPRIM | ID: wpr-761698

ABSTRACT

BACKGROUND: Hypertonic saline (HS) injections for decompressive neuroplasty (DN) can cause pain. We assessed whether a continuous infusion of HS through an infusion pump would reduce injection-related pain compared with repeated bolus administrations. METHODS: Fifty patients scheduled for DN were randomized to either the bolus injection or the continuous infusion group. After appropriately placing the epidural catheter, 4 mL of 5% NaCl was injected as four boluses of 1 mL each at 15-minute intervals or infused over 1 hour using an infusion pump. The severity of pain induced by HS injection, as measured by the 11-point numerical rating scale (NRS), was the primary outcome. The severity of low back or lower extremity pain, as measured by the 11-point NRS and Oswestry Disability Index (ODI), 3 months following the procedure, was the secondary outcome. RESULTS: Data from 21 patients in the bolus group and 23 in the continuous infusion group were analyzed. No statistically significant difference in injection-related pain was identified between the two groups during the initial HS administration (P = 0.846). However, there was a statistically significant reduction in injection-related pain in the continuous infusion group compared to the bolus injection group from the second assessment onwards (P = 0.001, < 0.001, and < 0.001, respectively). No significant between-group differences in the NRS and ODI scores 3 months post-procedure were noted (P = 0.614 and 0.949, respectively). CONCLUSIONS: Our study suggests that administering HS through a continuous infusion is a useful modality for reducing HS injection-related pain during DN.


Subject(s)
Humans , Catheters , Chronic Pain , Infusion Pumps , Injections, Epidural , Low Back Pain , Lower Extremity , Radiculopathy , Saline Solution, Hypertonic , Spinal Stenosis
16.
Rev. enferm. UERJ ; 26: e26388, jan.-dez. 2018. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-948549

ABSTRACT

Objetivo: determinar o perfil microbiológico de bactérias isoladas e identificadas nos leitos e bombas infusoras na unidade de terapia intensiva de um hospital universitário do Estado do Rio de Janeiro. Método: foram coletadas nove amostras de grades das camas dos pacientes e oito de teclados de bomba infusora de uma unidade de terapia intensiva, em outubro de 2014, delimitando-se uma área de 100cm² como parâmetro para ambas as coletas. As amostras foram coletadas através de swabs estéreis que foram umedecidos e transportados em Carry & Blair. Os microrganismos foram isolados, classificados e depois testados em relação à resistência antimicrobiana. Resultados: o gênero Staphylococcus coagulase negativa foi o mais prevalente. Os testes de suscetibilidade a antimicrobianos apontaram alguns destes Staphylococci como multirresistentes. Conclusão: chama-se atenção para a necessidade de ampliação do debate multiprofissional sobre questões de segurança hospitalar, apresentando a educação permanente como um possível caminho de sucesso no controle das infecções.


Objective: to determine the microbiological profile of bacteria isolated and identified from beds and infusion pumps in the intensive care unit of a university hospital in Rio de Janeiro state. Method: nine samples were collected from patients' bed side rails and eight from infusion pump keypads in an intensive care unit in October 2014. An area of 100cm² was delimited as the sampling parameter. Samples were collected using sterile swabs, which were wetted and transported with Cary-Blair. The microorganisms were isolated, classified, and then tested for antimicrobial resistance. Results: coagulase-negative Staphylococcus was the most prevalent type. Antimicrobial susceptibility testing indicated some of these Staphylococci were multi-drug resistant. Conclusion: multi-professional discussion of hospital safety issues must be expanded, and continuing professional development emerges as one possible pathway to success in nosocomial infection control.


Objetivo: determinar el perfil microbiológico de bacterias aisladas e identificadas en las camas y las bombas de infusión en la unidad de terapia intensiva de un hospital universitario de Rio de Janeiro. Método: se recolectaron nueve muestras de rejas de camas de pacientes y ocho de paneles de las bombas de infusión de una unidad de terapia intensiva, en octubre de 2014, delimitandose un área de 100 cm2 como parámetro para ambas recolecciones. Se recolectaron las muestras a través de swabs estériles que fueron humedecidos y transportados en Carry y Blair. Los microorganismos fueron aislados, clasificados y después probados repecto a la resistencia antimicrobiana. Resultados: el género Staphylococcus coagulasa negativo fue el más prevalente. Las pruebas de susceptibilidad a antimicrobianos mostraron algunos Staphylococci como resistentes a múltiples fármacos. Conclusión: se señala la necesidad de ampliación del debate entre los profesionales de la salud, sobre cuestiones de seguridad hospitalaria, presentando la educación permanente como un posible camino de éxito en el control de las infecciones.


Subject(s)
Bacteria/isolation & purification , Beds/microbiology , Infusion Pumps/microbiology , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Intensive Care Units , Brazil , Cross-Sectional Studies , Infection Control , Critical Care Nursing
17.
Acta sci., Biol. sci ; 40: 40972-40972, 20180000. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1460817

ABSTRACT

This study aimed to analyse the allelopathic bioactivity of fresh and infused aqueous extracts of Brazilian cherry leaves on the germination of lettuce and the initial development of maize. Brazilian cherry leaves were used to prepare a fresh aqueous extract (200 g L-1) and an infused extract (100 g L-1), which were diluted to concentrations of 0.4, 0.8, 1.2, 1.6 or 2.0% w/v. The variables evaluated in lettuce were the germination rate (GR), germination time index (GTI), germination speed index (GSI) and root length (RL). To determine the effect on the initial development of maize, we measured the shoot (SL) and root (RL) length. The experimental design included a factorial 2 × 5 design (two extracts and five concentrations), in addition to a control treatment (no extract). In general, the allelopathic bioactivity differed between the fresh and infused extracts. The fresh extract was more phytotoxic for the GR and RL of lettuce. Some beneficial results were observed for the infused extract, including an increase in the RL of lettuce and SL of maize. These effects were dependent on the extract concentration. Thus, there is evidence that Brazilian cherry extracts have allelopathic bioactivity.


O presente trabalho tem por objetivo em analisar a bioatividade alelopática do extrato fresco e infuso de pitangueira sobre a germinação de alface e no desenvolvimento inicial de milho. Para tanto, utilizaram-se folhas frescas de pitangueira para preparação de extratos aquosos fresco (200 g L-1) e infuso (100 g L-1), diluídos em 0,4; 0,6; 1,2; 1,6 e 2,0% p/v de concentração. Os parâmetros avaliados em alface foram porcentagem (PG), tempo médio (TMG) e velocidade média de germinação (VMG) e comprimento de raiz (CR). Já no desenvolvimento inicial do milho, obteve-se o comprimento de raiz (CR) e parte aérea (CPA). Os experimentos foram conduzidos em esquema fatorial 2x5 + tratamento controle (ausência de extrato), com dois tipos de extratos e cinco concentrações. De modo geral, a bioatividade alelopática dos extratos frescos e infusos foi diferente, sendo que o extrato fresco mostrou-se fitotóxico sobre a PG e CR de alface. Alguns resultados benéficos foram observados com o extrato infuso como aumento no CR de alface e no CPA de milho. Os efeitos desses extratos dependem das concentrações onde são testados. Dessa forma, há evidência de que os extratos de pitangueira possuem bioatividade alelopática.


Subject(s)
Allelopathy , Infusion Pumps , Eugenia/cytology , Eugenia/chemistry , Zea mays/chemistry
18.
Journal of Korean Biological Nursing Science ; : 228-235, 2018.
Article in Korean | WPRIM | ID: wpr-740798

ABSTRACT

PURPOSE: This study aimed to investigate the clinical alarm occurrence and management of nurses toward clinical alarms in the intensive care unit (ICU). METHODS: This observational study was conducted with 40 patients and nurses cases in two ICUs of a university hospital. This study divided 24 hours into the unit of an hour and conducted two times of direct observation per unit hour for 48 hours targeting the medical devices applied to 40 patients. Data were analyzed using IBM SPSS Statistics 23. RESULTS: On average, 3.8 units of medical devices were applied for each patient and the ranges of alarm settings were wide. During 48 hours, 184 cases of clinical alarm were occurred by four types of medical devices including physiological monitors, mechanical ventilators, infusion pumps, and continuous renal replacement therapy. Among them, false alarm was 110 cases (59.8%). As for the alarm management by ICU nurses, two-minute alarm mute took up most at 38.0% (70 cases), and no response was second most at 32.6% (60 cases). When valid alarm sounded, nurses showed no response at 43.2%. CONCLUSION: The findings suggest that a standard protocol for alarm management should be developed for Korean ICU settings. Based on the protocol, continuous training and education should be provided to nurses for appropriate alarm management.


Subject(s)
Humans , Clinical Alarms , Critical Care , Education , Infusion Pumps , Intensive Care Units , Observational Study , Renal Replacement Therapy , Ventilators, Mechanical
19.
Acta neurol. colomb ; 34(1): 25-39, 2018. tab, GRAF
Article in Spanish | LILACS, COLNAL | ID: biblio-909100

ABSTRACT

La apomorfina es un agonista dopa que se viene usando desde hace más 25 años en el tratamiento de la enfermedad de Parkinson avanzada con complicaciones motoras complejas, por lo cual sigue siendo de gran importancia en el tratamiento de esta etapa de la enfermedad. En el siguiente escrito, realizado por el Comité de Movimientos Anormales de la Asociación Colombiana de Neurología, se hace una revisión respecto a la medicación, su eficacia y el papel en el manejo de la enfermedad de Parkinson, así como una comparación entre las diferentes terapias avanzadas disponibles hoy en día. De la misma manera el Comité hace recomendaciones sobre las indicaciones, elección de candidatos y protocolos para el inicio de las diferentes formas de administración (intermitente e infusión continua) para optimizar el uso de esta terapia y facilitar la adherencia al tratamiento. Por otra parte, se revisan los efectos adversos relacionados con la terapia y se hacen recomendaciones sobre el manejo de las mismas, el seguimiento que se debe hacer a los pacientes que reciban apomorfina y las claves en el tratamiento a largo plazo. long term.


Apomorphine is a dopamine agonist that has been used for more than 25 years in the treatment of advanced Parkinson's disease with complex motor complications, becoming an important treatment option for this stage of the disease. In the following document, written by the movement disorders committee of the Colombian Association of Neurology, an extensive review is made about this medication, its efficacy and role in the management of Parkinson's disease as well as a comparison between the different advanced therapies available today. Additionally, recommendations about the indications, election of candidates and protocols for choosing between the different forms of administration (intermittent and continuous infusion) are establish according current evidence in order to help clinicians to optimize the use of this therapy and facilitate adherence to treatment. On the other hand, adverse effects related to the therapy are reviewed and recommendations are made about their management, as well as a protocol to follow-up patients receiving apomorphine and keys in the long term.


Subject(s)
Humans , Parkinson Disease , Infusion Pumps , Apomorphine , Consensus
20.
Rev. latinoam. enferm. (Online) ; 26: e3053, 2018. tab, graf
Article in English | LILACS, BDENF | ID: biblio-961159

ABSTRACT

ABSTRACT Objective: To evaluate the hemolysis biomarkers of packed red blood cells transfused by two different linear peristaltic infusion pumps at two infusion rates. Method: An experimental and randomized study was designed simulating the clinical practice of transfusion. Two linear peristaltic infusion pumps from different manufactures were studied in triplicate at 100 mL/h and 300mL/h infusion rates. The chosen hemolysis biomarkers were total hemoglobin, free hemoglobin, hematocrit, potassium and degree of hemolysis. They were analyzed before and after each infusion. Results: Potassium showed statistically significant variations in all scenarios of the experiment (P<0.010). In a separated analysis, potassium increased mainly at 300mL/h rate (P=0.021) and free hemoglobin had significant variation when comparing infusion pumps from different manufacturers (P=0.026). Although hematocrit, total hemoglobin and degree of hemolysis had increased after infusion, no statistically significance variations were identified. Conclusions: Hemolysis risk induced by a linear peristaltic infusion pump was identified by an increase in free hemoglobin and potassium markers. As the potassium biomarker is often increased in aged packed red blood cells, we do not recommend using them in this scenario. Additional studies should be performed about other markers and using larger samples in order to reinforce the transfusion practice in nursing.


RESUMO Objetivo: avaliar os biomarcadores de hemólise de concentrado de hemácias transfundidos por duas bombas de infusão peristáltica linear distintas, em duas taxas de infusão. Método: estudo experimental randomizado desenhado para simular a prática clínica da transfusão. Duas bombas de infusão peristáltica linear de diferentes fabricantes foram estudadas em triplicata a 100 ml/h e 300 mL/h de infusão. Os biomarcadores de hemólise escolhidos foram hemoglobina total, hemoglobina livre, hematócrito, potássio e grau de hemólise. Eles foram analisados antes e após cada infusão. Resultados: o potássio apresentou variações estatisticamente significativas em todos os cenários do experimento (P < 0,010). Em análise separada, o potássio aumentou principalmente na taxa de 300 mL/h (P = 0,021) e a hemoglobina livre teve uma variação significativa no experimento comparando bombas de infusão de diferentes fabricantes (P = 0,026). Embora o hematócrito, a hemoglobina total e o grau de hemólise tenham aumentado após a infusão, não foram identificadas variações estatisticamente significativas. Conclusões: o risco de hemólise induzido por bombas de infusão peristáltica linear foi identificado com base em um aumento nos marcadores de hemoglobina livre e potássio. Como o biomarcador potássio é frequentemente aumentado em concentrados de hemácias envelhecidos, não se recomenda usá-los nesse cenário e estudos adicionais podem ser realizados. Vale a pena realizar estudos sobre outros marcadores e utilizar amostras maiores para fundamentar a prática de enfermagem transfusional.


RESUMEN Objetivo: evaluar los biomarcadores de hemólisis de concentrados de glóbulos rojos transfundidos por dos bombas de infusión peristálticas lineales diferentes a dos velocidades de infusión. Método: se hizo un estudio experimental y aleatorizado que simula la práctica clínica de la transfusión. Se estudiaron dos bombas de infusión peristálticas lineales de diferentes fabricantes por triplicado a velocidades de infusión de 100 ml/h y 300 ml/h. Los biomarcadores de hemólisis elegidos fueron la hemoglobina total, la hemoglobina libre, el hematocrito, el potasio y el grado de hemólisis. Fueron analizados antes y después de cada infusión. Resultados: El potasio mostró variaciones estadísticamente significativas en todos los escenarios del experimento (P <0.010). En análisis separados, el potasio aumentó principalmente a una tasa de 300 ml/h (P=0.021) y la hemoglobina libre tuvo una variación significativa en un experimento de un fabricante de bomba de infusión (P=0.026). Aunque el hematocrito, la hemoglobina total y el grado de hemólisis aumentaron después de la infusión, no se identificaron variaciones estadísticamente significativas. Conclusiones: el riesgo de hemólisis inducido por una bomba de infusión peristáltica lineal se identificó por un aumento en la hemoglobina libre y los marcadores de potasio. Debido a que el biomarcador de potasio a menudo aumenta en los glóbulos rojos concentrados de edad, no recomendamos utilizarlos en este escenario y se podrían realizar estudios adicionales. Vale la pena realizar estudios sobre otros marcadores y el uso de muestras más grandes para fundamentar la práctica de enfermería de transfusión de sangre.


Subject(s)
Humans , Male , Female , Blood Transfusion/methods , Erythrocytes/immunology , Hemolysis , Infusion Pumps , Patient Safety